Chemicals for Konica (Film) Minilabs

See also : Chemicals for Konica (Paper) Minilabs

Index
Chemicals for Konica CNK-4-52 process for Konica NPS 8-series and 612QA minilabs
Chemicals for Konica CNK-4-52 LR process for Konica NPS 8-series and 612QA minilabs
Chemicals for Konica CNK-4-40 process for Konica NPS 4,5,6-series

Chemicals for Konica CNK-4-52 process


The following products are recommended for use with Konica NPS 8-series and 612QA (with CL KP50E) non-Ecojet (i.e. liquid chemistry type) film processors using the Konica CNK-4-52 process :

Product

EnviroNeg Developer Replenisher Kit LR AC †
EnviroNeg RA Bleach Replenisher AC *
Negacolor RA Fixer & Replenisher
EnviroNeg FF Superflo Stab MB AC


Starters

EnviroNeg Universal Developer Starter AC (for preparation of new developer tank solutions)

To Make

2 x 10 L
2 x 5 L
4 x 10 L
2x (10x10L) (dosing bottle)




6 x 1 L concentrate
Cat No.

954 743
971 135
992 024
991 596




972 497
* Air Control odour-free product


A Product Information Sheet (PIS) giving additional details, mixing instructions and technical information about Konica CNK-4-52 equivalent film chemistry can be found on our esclusivo web site for authorised users.
† If you have very low throughput on your Konica processor, you may wish to consider use of the standard EnviroNeg Developer at 43ml/135-24 film, or even our new EnviroNeg Developer Replenisher 60 AC at 60 ml/135-24 film (and also EnviroNeg RA Bleach 10 AC) for the best possible negative quality. Please ask your FUJIFILM representative for more details.

See also : Chemicals for Konica (Paper) Minilabs
Return to : Chemicals for Konica (Film) Minilabs Index



Chemicals for Konica CNK-4-52 LR process

The following products are recommended for use with Konica NPS 8-series and 612QA (with CL KP50E) non-Ecojet (i.e. liquid chemistry type) film processors using the Konica CNK-4-52 LR process

Product

EnviroNeg Developer Replenisher Kit LR AC
EnviroNeg RA Bleach Replenisher AC
Negacolor RA Fixer & Replenisher
EnviroNeg FF Superflo Stab MB AC


Starters

EnviroNeg Universal Developer Starter AC (for preparation of new developer tank solutions)

To Make

2 x 10 L
2 x 5 L
4 x 10 L
2x (10x10L) (dosing bottle)




6 x 1 L concentrate

Cat No.

954 743
971 135
992 024
991 596




972 497

Due to the continuing rapid decrease in film volumes, Fuji Hunt do not recommend continued use of very low replenishment rate developers for the C41 process. Therefore we recommend use of EnviroNeg Developer LR (21 ml/135-24 film) instead of the Konica C41 LR developer at 15ml / 135-24 film. This will require a change in replenishment rate setting. Please see the Product Information Sheet for full details. If you have very low throughput on your Konica processor, you may wish to consider use of the standard EnviroNeg Developer at 43ml/135-24 film, or even our new EnviroNeg Developer Replenisher 60 AC at 60 ml/135-24 film (and also EnviroNeg RA Bleach 10 AC) for the best possible negative quality. Please ask your FUJIFILM representative for more details.

A Product Information Sheet (PIS) giving additional details, mixing instructions and technical information about Konica CNK-4-52 LR equivalent film chemistry can be found on our esclusivo web site for authorised users.

See also : Chemicals for Konica (Paper) Minilabs
Return to : Chemicals for Konica (Film) Minilabs Index




Chemicals for Konica CNK-4-40 process

The following products are recommended for use with Konica NPS 4, 5 & 6-series film processors using the Konica CNK-4-40 process

Product

EnviroNeg Developer Replenisher AC
EnviroNeg B Bleach 3 Replenisher LR AC
Negacolor RA Fixer & Replenisher
Negacolor Superflo Stabilizer & Replenisher
EnviroNeg FF Superflo Stab MB AC


Starters

EnviroNeg Universal Developer Starter AC (for preparation of new developer tank solutions)

EnviroNeg Bleach Starter AC

To Make

2 x 10 L
2 x 5 L
4 x 10 L
10 x 10L
2x (10x10L) (dosing bottle)





6 x 1 L concentrate

2 x 5L conc

Cat No.

954 693
971 895
992 024
929 349
991 596





972 497

971 143

Please see the Product Information Sheet for full details.

A Product Information Sheet (PIS) giving additional details, mixing instructions and technical information about Konica CNK-4-40 equivalent film chemistry can be found on our esclusivo web site for authorised users. If you have very low throughput on your Konica processor, you may wish to consider use of the standard EnviroNeg Developer at 43ml/135-24 film, or even our new EnviroNeg Developer Replenisher 60 AC at 60 ml/135-24 film for the best possible negative quality. Please ask your FUJIFILM representative for more details.

See also : Chemicals for Konica (Paper) Minilabs